ATMOSPHERE COPYRIGHT © 2016
Ventilation Products
Manufacturer
VTX400P & C air performance graph
220 CFM
VTX400P & C at 0 static pressure
Dial-A-Temp
Vari-Speed
Mounting Brackets (MBK 95)
Backdraft Damper (4”)
VTX400P & C
Downloadable VTX400P & VTX400C PDF Files
CONFORMS TO UL 507 and CSA C22.2 no.113
VTX400P & C accessories
Powerfully engineered
Fan air flow performance shall be based on tests conducted in accordance with AMCA Standard 211 and shall be licensed to bear the AMCA Certified Ratings label
4" Lint Trap
Weight : 8.8 lbs.
All VTX products incorporate motors suitable for 120 Volts AC 60Hz electrical supply only
VTX400P & C performance data
Performance certified is for installation type D - Ducted inlet, Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings include the effects of appurtenances (accessories) Inlet Duct, Inlet Bell, Outlet Duct
VTX400P weight & dimensions
Weight : 7.4 lbs.
VTX400C weight & dimensions
Vortex Powerfans VTX400P & VTX400C inline blowers, for 4 in diameter duct, are ideal to solve the problems caused by long duct runs on clothes dryers. In a clothing dryer application, when the dryer is turned on, the VTX400P and VTX400C will automatically turn on.
The VTX400P has a built in automatic pressure switch that detects when air is flowing through the ventilation duct. It will automatically turn on for a period of 10 minutes and shut off for a period of 15 seconds and turn back on if there is still positive pressure from the dryer.
The VTX400C is supplied with a current sensor that detects when the dryer is turned on to automatically activate the fan. The current sensor is available either with or without a five minute turn off time delay.
Dryer duct boosting is typically required when duct length exceeds:
When is a dryer duct booster required?
Every bend is equal to 5 linear feet.
When installing a clothing dryer duct exhaust system, please ensure to follow all applicable building codes and manufacture’s recommendations.
Ideal clothing dryer venting arrangements with short duct length are often not possible. Both commercial and residential clothing dryers should normally dry the clothing in a timely matter. Due to venting restrictions, clothing dryers with longer duct lengths will typically take a longer time to dry and consequently consume more power. An inline vent boosting blower is a smart solution to this problem.
Dry Facts
2 different typical installations
Roof or Wall exhaust
Roof exhaust
Wall exhaust